Temporary cooling · North Texas

Temporary chiller rental in Dallas–Fort Worth

Zebrix Group Inc. rents temporary and portable chillers for facilities in Dallas–Fort Worth: data centers, hospitals, campuses, offices and industrial plants that need chilled water during a planned shutdown, an unexpected chiller failure or a hot summer that outruns the plant. We size the chiller to the building's real cooling load, tie it into the existing chilled-water loop and plan its power, so the building keeps cooling normally while the permanent plant is down.

Chillers for North Texas data centers and critical facilities

Dallas–Fort Worth has one of the largest concentrations of data centers in the country, alongside major hospital systems, universities and distribution centers. These buildings can't let critical spaces warm up while a chiller is repaired or replaced, so the temporary chiller has to be running and carrying load before the permanent unit is isolated. We plan the changeover with your facilities team and test it in both directions.

Planning a DFW rental with a Houston-area team

Zebrix is based in The Woodlands, north of Houston, and takes on chiller rentals across Texas, including Dallas–Fort Worth. For planned shutdowns, bring us in early so equipment, crews and power are scheduled around your outage window. For an emergency, send what you know about the building and the failed chiller, and we'll tell you plainly what we can set up and when.

Sizing for a North Texas summer

We size from the building's actual peak cooling load, ideally from building automation trend data for the hottest weeks, not from the nameplate of the chiller being replaced. North Texas summer afternoons push loads well above the spring and fall numbers many shutdowns are planned around, so we check the plan against peak weather before choosing equipment.

Connection and power

We locate tie-in points, isolation valves and pump capacity on the chilled-water loop, and plan temporary pumps and hoses where the existing ones can't do the job. Portable chillers need a large electrical supply; if the building's chiller circuit is part of the work or there isn't enough spare capacity near the pad, we add a generator and temporary power distribution.

What to send us for a quote

A quote for a DFW site is fastest when we have these up front.

  • The building's peak cooling load, or building automation trend data we can size from.
  • The site address, where the chiller can sit and how a truck reaches it.
  • The electrical power available near that spot, or whether you need a generator too.
  • The chilled-water tie-in points, with photos of valves and connections if you have them.
  • The outage dates, or the date the existing chiller failed.

Where we deliver in North Texas

We take on chiller rentals across Dallas–Fort Worth, including Dallas, Fort Worth, Arlington, Irving, Plano, Garland, Richardson, Carrollton, Grand Prairie, Frisco, McKinney, Allen and Denton, and at facilities elsewhere in Texas.

One team for the work and the rental

Because Zebrix is also the HVAC and mechanical contractor, the people who size and connect the rental are the same people who understand the system it is carrying. There is no hand-off between a rental company and a mechanical crew.

Certified and licensed. SBA-certified service-disabled veteran-owned small business (SDVOSB), Texas VetHUB certified (VID 21829539), and TDLR Air Conditioning & Refrigeration Contractor license TACLA00169073C. Based in The Woodlands, serving Greater Houston and Texas.

Frequently asked questions

Do you rent chillers in Dallas and Fort Worth?

Yes. Zebrix is based in The Woodlands and takes on temporary and portable chiller rentals across Dallas–Fort Worth, sized to the building's load and tied into its chilled-water loop.

How early should we book a chiller rental for a planned shutdown in DFW?

As early as the outage date is known, and earlier for work between May and September, when rental equipment is in highest demand. That leaves time to size the chiller, plan power and test the changeover before the existing chiller is isolated.

Can a temporary chiller support a data center during a chiller replacement?

Yes. We size it to the data hall's real load, tie it into the chilled-water loop and have it running and carrying load before the permanent chiller is isolated, then keep it in place until the new unit is commissioned and stable.

What do you need to quote a chiller rental in Dallas–Fort Worth?

The building's peak cooling load or trend data, the site address and where the chiller can sit, the power available nearby, the chilled-water tie-in points and the outage dates.