Temporary power
Temporary power and generator rental in Texas
Zebrix Group Inc. provides temporary power rental across Texas: portable and standby generators with the cables and temporary power distribution to connect them, for maintenance shutdowns, emergencies, peak demand and mechanical work. We size each generator for the equipment it actually has to run, including the starting demand of chillers and pumps, and plan the distribution, refueling and placement with the rest of the job.
Common reasons to rent a generator
Generators fill the gap when building power isn't available or isn't enough.
- Running temporary chillers and pumps while a building's chiller circuit is out of service.
- Keeping critical systems up during electrical or mechanical maintenance.
- Emergency power after equipment or utility failures.
- Covering peak demand beyond what the permanent service can carry.
Sizing for the real load
Motors draw far more power when they start than when they run, so a generator for cooling equipment has to cover the chiller's full-load and starting demand plus any pumps, not just the running load. We size from the equipment list and the mechanical scope, so the generator matches the outage.
Standby or prime power, and which fuel
A standby generator sits ready and takes over only when the normal source fails. A prime-power generator is the main source for the length of the job and runs long hours. The difference changes how it is sized, how often it is refueled and how it is connected. Most rental generators run on diesel, which can be delivered anywhere a truck can reach. Natural gas avoids refueling where the site has a gas connection big enough for the generator, which helps on long outages and at sites with strict fuel-storage limits.
Distribution, fuel and permits
Power has to get from the generator to the equipment safely. We plan the cables, panels and connection points, the refueling schedule, and where the generator sits. Before it arrives, we check local noise limits, fuel storage rules and any permits for temporary equipment.
Temporary power for critical facilities and construction work
Data centers, hospitals, labs and other critical facilities can't simply switch off cooling or controls while electrical or mechanical work is done. We plan temporary power around the outage window so critical systems stay up, and have the generator running and tested before the permanent source is taken down. On mechanical construction and renovation work, the same temporary power can carry chillers, pumps and other equipment until the permanent service is ready.
What to send us for a temporary power quote
The more of this we have up front, the more exact the first quote is.
- The equipment the generator has to run, with nameplates or the mechanical scope if you have them.
- The voltage and phase the equipment needs, and where it will connect.
- The site address, where the generator can sit and how a truck gets in.
- Start and end dates, the hours it will run, and whether it's a standby or the main source.
- Who supplies fuel, and any noise or fuel-storage limits at the site.
One team for the work and the rental
Because Zebrix is also the HVAC and mechanical contractor, the people who size and connect the rental are the same people who understand the system it is carrying. There is no hand-off between a rental company and a mechanical crew.
Frequently asked questions
Is temporary power rental the same as generator rental?
- Mostly. Temporary power rental is the generator plus everything that gets its power to the equipment: cables, temporary power distribution and the connection plan. We rent and plan them together so the generator arrives ready to carry the load.
What information do you need to quote a generator rental?
- The equipment it has to run, the voltage and phase, the site address and where the generator can sit, the start and end dates with expected run hours, and who supplies fuel. Nameplates or the mechanical scope let us size for starting demand.
How do you size a generator for cooling equipment?
- For the equipment's full-load and starting demand, not just its running load. Motors on chillers and pumps draw far more power when they start, so we size from the equipment list and the mechanical scope.
Diesel or natural gas generator rental?
- Diesel is the usual choice because fuel can be delivered to almost any site. Natural gas avoids refueling where the site has a gas connection big enough for the generator, which helps on long jobs and where fuel storage is limited. We recommend one after looking at the site, the run hours and the local rules.
Do you provide cables and temporary power distribution?
- Yes. We rent temporary power distribution alongside portable and standby generators, and plan the cables, panels and connection points as part of the job.
What about fuel, noise and permits?
- We plan the refueling schedule and the generator's placement, and check local noise limits, fuel storage rules and any permits for temporary equipment before it arrives.
Can Texas agencies rent from Zebrix as an SDVOSB and VetHUB vendor?
- Yes. Zebrix is an SBA-certified SDVOSB and Texas VetHUB certified (VID 21829539), and equipment rental is registered under NAICS 532412 and 532490 and the 975 NIGP class.